2300DCCCE-2CB8-4711-B175-7CD46B37E5896414EB90-3D98-4E24-88A0-5C84A02DB98979F6311B-33D0-4B2B-AD0B-0F94D47627C8Easy9 Residual Current Circuit Breaker - 4P - 63 A - 30 mA - AC type - 400 VS/EZ9R03463581088.859.0000Range of product: Easy9 Product or component type: Residual current circuit breaker (RCCB) Device short name: Easy9 RCCB Poles: 4P Neutral position: Left [In] rated current: 63 A Network type: AC Earth-leakage sensitivity: 30 mA Earth-leakage protection time delay: Instantaneous Earth-leakage protection class: Type AC Rated breaking and making capacity: 500 A Rated conditional short-circuit current: Easy9 MCB: 3000 A 63 AEASY963A4P download-catalogue/schneider/distribution/ez9r03463-document.pdf1|2024-09-19:04:003:2023-01-10_11-40-05Schneider Electric\Distribution\Circuit Breaker and Accessories\Earth Leakage6414EB90-3D98-4E24-88A0-5C84A02DB989SEZ9R03463.jpgSEZ9R03463.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1946.830011
240860B71-9219-4AA6-B90F-3F7D128DC0526414EB90-3D98-4E24-88A0-5C84A02DB98979F6311B-33D0-4B2B-AD0B-0F94D47627C8Easy9 Residual Current Circuit Breaker - 2P - 63 A - 30 mA - AC type - 230 VS/EZ9R0326357507.69126.0000Range of product: Easy9 Product or component type: Residual current circuit breaker (RCCB) Device short name: Easy9 RCCB Poles: 2P Neutral position: Left [In] rated current: 63 A Network type: AC Earth-leakage sensitivity: 30 mA Earth-leakage protection time delay: Instantaneous Earth-leakage protection class: Type AC Rated breaking and making capacity: 500 A Rated conditional short-circuit current: Easy9 MCB: 3000 A 63 AEASY963A2P download-catalogue/schneider/distribution/ez9r03263-document.pdf1|2024-09-19:04:001:2022-11-16_09-46-28|1:2022-11-16_09-46-38|2:2023-01-25_10-42-33|2:2023-01-25_10-42-35|2:2023-01-25_10-42-38|1:2023-02-05_23-19-24|1:2023-02-05_23-19-28|1:2023-02-05_23-19-43|7:2023-02-12_11-37-23|7:2023-02-12_11-37-35|4:2023-02-27_14-39-05|4:2023-02-27_14-39-14|4:2023-02-27_14-39-32|1:2023-03-02_13-05-05|1:2023-03-02_13-05-12|1:2023-03-02_13-05-27|1:2023-03-06_13-54-54|1:2023-03-06_13-54-58|1:2023-03-06_13-55-12|2:2023-03-06_17-28-58|2:2023-03-06_17-29-02|2:2023-03-06_17-29-09|2:2023-03-06_17-29-12|2:2023-03-06_17-29-21|2:2023-03-06_17-29-26|2:2023-03-06_17-29-31|5:2023-04-14_19-20-51|5:2023-04-14_19-20-54|5:2023-04-14_19-21-02|5:2023-04-14_19-21-09|5:2023-04-14_19-21-21|5:2023-04-14_19-21-27|1:2023-09-06_21-59-39|1:2023-09-06_21-59-47|1:2023-09-06_21-59-54|1:2023-09-06_22-00-06Schneider Electric\Distribution\Circuit Breaker and Accessories\Earth Leakage6414EB90-3D98-4E24-88A0-5C84A02DB989SEZ9R03263.jpgSEZ9R03263.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1441.470011
229CC3872-3B8A-4099-8164-D4D6B528E804025F973C-7FE4-4877-9763-DFDCA41CE71379F6311B-33D0-4B2B-AD0B-0F94D47627C8Vigi iC60 - earth leakage add-on block - 2P - 40A - 30mA - AC typeS/A9V41240553460.72Range: Acti 9 Product or component type: Add-on residual current devices Device short name: Vigi iC60 Poles description: 2P [In] rated current: 40 A Earth-leakage sensitivity: 30 mA Earth-leakage protection time delay: Instantaneous Earth leakage protection type: Type AC Network type: AC Network frequency: 50/60 Hz [Ue] rated operational voltage: - 230...240 V AC 50/60 Hz conforming to EN 61009-1 - 230...240 V AC 50/60 Hz conforming to IEC 61009-1 Standards: - EN 61009-1 - IEC 61009-1 9 mm pitches: 4ACTI940A2P download-catalogue/schneider/distribution/a9v41240-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Earth Leakage Module025F973C-7FE4-4877-9763-DFDCA41CE713SA9V41240.jpgSA9V41240.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric13009.320011
297B75D7F-BCC9-4BE1-9B08-8D1C25A0CFE3025F973C-7FE4-4877-9763-DFDCA41CE713Vigi iC60 - earth leakage add-on block - 2P - 25A - 30mA - AC typeS/A9V412255572646.9213.0000Range: Acti 9 Product or component type: Add-on residual current devices Device short name: Vigi iC60 Poles description: 2P [In] rated current: 25 A Earth-leakage sensitivity: 30mA Earth-leakage protection time delay: Instantaneous Earth leakage protection type: Type AC Network type: AC Network frequency: 50/60 Hz [Ue] rated operational voltage: 230/400 V AC 50/60 Hz conforming to EN 61009-1 230/415 V AC 50/60 Hz conforming to IEC 61009-1 Standards IEC 61009-1 EN 61009-ACTI925A2Pdownload-catalogue/schneider/distribution/a9v41225-acti-document.pdf1|2024-09-19:04:001:2023-03-29_17-09-44|1:2023-03-29_17-09-55|1:2023-03-29_17-10-01|1:2023-03-29_17-10-14|1:2023-03-29_17-10-21Schneider Electric\Distribution\Circuit Breaker and Accessories\Earth Leakage Module025F973C-7FE4-4877-9763-DFDCA41CE713A9V41225.jpgA9V41225.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric12301.670011
2F1F0B972-1A85-42D0-A31E-7A7917168507F7B13952-5A20-43DA-8584-24158D411B8B79F6311B-33D0-4B2B-AD0B-0F94D47627C8switch disconnector, Compact INS63 , 63 A, standard version with black rotary handle, 3 polesS/28902552094.87Range: ComPact Product name: Compact INS Product or component type: Switch disconnector Poles description: 3P Network type: DC/AC Network frequency: 50/60 Hz [Ie] rated operational current: - AC-22A: 63 A AC 50/60 Hz 220/240 V - AC-22A: 63 A AC 50/60 Hz 380/415 V - AC-22A: 63 A AC 50/60 Hz 440/480 V - AC-22A: 63 A AC 50/60 Hz 500 V - AC-23A: 40 A AC 50/60 Hz 500 V - AC-23A: 63 A AC 50/60 Hz 220/240 V - AC-23A: 63 A AC 50/60 Hz 380/415 V - AC-23A: 63 A AC 50/60 Hz 440/480 V - DC-22A: 63 A DC 125 V 2 poles in series - DC-23A: 63 A DC 125 V 2 poles in series [Ui] rated insulation voltage: 690 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 8 kV [Ith] conventional free air thermal current: 63 A at 60 °C [Icm] rated short-circuit making capacity: - 15 kA switch-disconnector alone 500 V AC at 50/60 Hz - 75 kA with upstream protection circuit breaker 500 V AC at 50/60 Hz [Ue] rated operational voltage: - 125 V DC - 500 V AC 50/60 Hz Suitability for isolation: Yes Contact position indicator: Yes Visible break: No Pollution degree: 3COMPACT INS / INV63A3Pdownload-catalogue/schneider/distribution/28902-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\IsolatorF7B13952-5A20-43DA-8584-24158D411B8BS28902.jpgS28902.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11821.630011
2001105D1-2C35-43F9-94D4-3621CD4B550853AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60a, 2P, 63 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F64263522975.6731.0000
Over-voltage resistance by high level of industrial performances conception (pollution degree, rated impulse withstand voltage and insulation voltage)
High performance limitation
Fast closing independent of the speed of actuation of the toggle
Remote indication, open/close/tripped, by optional auxiliary contacts
Top or bottom electrical feeding
Class 2 front face
Promises absolute protection against electric shocks
iC60a circuit breakers are multi-standard circuit breakers which combine the following functions
Circuit protection against short-circuit currents
Circuit protection against overload currents
Suitable for industrial isolation according to IEC/EN 60947-2, standard
Colour: White, black and green Poles: 2P Breaking capacity: 6kA Rated voltage: 220/415V Curve code: C-Curve Technical document: DownloadACTI963A2P6KACdownload-catalogue/schneider/distribution/a9f64263-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64263_Schneider_Acti9/20210217T0659/3603dobject>2:2023-02-02_13-47-05|2:2023-02-02_13-47-09|2:2023-02-02_13-47-20|2:2023-02-02_13-47-25|2:2023-02-02_13-47-37|2:2023-02-02_13-47-42|2:2023-02-02_13-47-57|2:2023-03-15_10-20-17|2:2023-03-15_10-20-23|2:2023-03-15_10-20-30|1:2023-07-24_06-56-55|1:2023-07-24_06-57-03|1:2023-07-24_06-57-08|1:2023-07-24_06-57-15|1:2023-07-24_06-57-21|1:2023-07-24_06-57-27|1:2023-07-24_06-57-34Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F64263.jpgA9F64263.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1848.410011
202BB0756-56CE-4B38-A2D3-E9D6317C08F053AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 1P, 16 A, C curve, 3 kAS/EZ9F5311657970.1862.0000Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 1P Number of protected poles: 1 [In] rated current: 16 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 230 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY916A1P3KAC download-catalogue/schneider/distribution/ez9f53116-document.pdf1|2024-09-19:04:001:2022-11-16_09-46-32|1:2022-11-16_09-46-40|2:2023-03-06_17-28-58|2:2023-03-06_17-29-02|2:2023-03-06_17-29-08|2:2023-03-06_17-29-12|2:2023-03-06_17-29-20|2:2023-03-06_17-29-25|2:2023-03-06_17-29-30|10:2023-03-24_10-32-49|10:2023-03-24_10-32-59|10:2023-03-24_10-33-03Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53116.jpgSEZ9F53116.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric161.030011
208233B56-C78E-4C28-AC0D-9687B9E609EC53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60N, 3 pole, 40 A, D curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F753405411812.46Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 3P Number of protected poles: 3 [In] rated current: 40A Network type: AC DC Trip unit technology: Thermal-magnetic Curve code: DACTI940A3P10KADdownload-catalogue/schneider/distribution/a9f75340-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F75340_Image-StopMotion/20200616T0147/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F75340.jpgA9F75340.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11576.050011
208CDF32E-7C8D-46B2-8BFD-D81BDEE3CB8653AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60a, 3P, 16 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F643165251106.6318.0000
Over-voltage resistance by high level of industrial performances conception (pollution degree, rated impulse withstand voltage and insulation voltage)
High performance limitation
Fast closing independent of the speed of actuation of the toggle
Remote indication, open/close/tripped, by optional auxiliary contacts
Top or bottom electrical feeding
Class 2 front face
Promises absolute protection against electric shocks
iC60a circuit breakers are multi-standard circuit breakers which combine the following functions
Circuit protection against short-circuit currents
Circuit protection against overload currents
Suitable for industrial isolation according to IEC/EN 60947-2, standard
Colour: White, black and green Poles: 2P Breaking capacity: 6kA Rated voltage: 220/415V Curve code: C-Curve Technical document: DownloadACTI916A3P6KACdownload-catalogue/schneider/distribution/a9f64316-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64316_Schneider_Acti9/20210205T1447/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F64316.jpgA9F64316.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1962.290011
20A6B2752-07CA-421A-9791-6B585E834CCC53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60a, 3P, 63 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F643635311233.04110.0000
Over-voltage resistance by high level of industrial performances conception (pollution degree, rated impulse withstand voltage and insulation voltage)
High performance limitation
Fast closing independent of the speed of actuation of the toggle
Remote indication, open/close/tripped, by optional auxiliary contacts
Top or bottom electrical feeding
Class 2 front face
Promises absolute protection against electric shocks
iC60a circuit breakers are multi-standard circuit breakers which combine the following functions
Circuit protection against short-circuit currents
Circuit protection against overload currents
Suitable for industrial isolation according to IEC/EN 60947-2, standard
Colour: White, black and green Poles: 3P Breaking capacity: 6kA Rated voltage: 220/415V Curve code: C-Curve Technical document: DownloadACTI963A3P6KACdownload-catalogue/schneider/distribution/a9f64363-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64363_Schneider_Acti9/20210205T1447/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F64363.jpgA9F64363.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11072.210011
20D0A807C-6C58-42F9-BD4B-FDF167D856BB53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60a, 2P, 2 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F64202513983.9713.0000
Over-voltage resistance by high level of industrial performances conception (pollution degree, rated impulse withstand voltage and insulation voltage)
High performance limitation
Fast closing independent of the speed of actuation of the toggle
Remote indication, open/close/tripped, by optional auxiliary contacts
Top or bottom electrical feeding
Class 2 front face
Promises absolute protection against electric shocks
iC60a circuit breakers are multi-standard circuit breakers which combine the following functions
Circuit protection against short-circuit currents
Circuit protection against overload currents
Suitable for industrial isolation according to IEC/EN 60947-2, standard
Colour: White, black and green Poles: 2P Breaking capacity: 6kA Rated voltage: 220/415V Curve code: C-Curve Technical document: DownloadACTI92A2P6KACdownload-catalogue/schneider/distribution/a9f64202-act-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64202_Schneider_Acti9/20210217T0659/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F64202.jpgA9F64202.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1855.630011
20DCDE433-ED3A-4854-891A-E0289506429A53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60a, 2P, 32 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F64232519917.628.0000
Over-voltage resistance by high level of industrial performances conception (pollution degree, rated impulse withstand voltage and insulation voltage)
High performance limitation
Fast closing independent of the speed of actuation of the toggle
Remote indication, open/close/tripped, by optional auxiliary contacts
Top or bottom electrical feeding
Class 2 front face
Promises absolute protection against electric shocks
iC60a circuit breakers are multi-standard circuit breakers which combine the following functions
Circuit protection against short-circuit currents
Circuit protection against overload currents
Suitable for industrial isolation according to IEC/EN 60947-2, standard
Colour: White, black and green Poles: 2P Breaking capacity: 6kA Rated voltage: 220/415V Curve code: C-Curve Technical document: DownloadACTI932A2P6KACdownload-catalogue/schneider/distribution/a9f64232-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64232_Schneider_Acti9/20210217T0659/3603dobject>2:2023-03-15_10-20-17|2:2023-03-15_10-20-23|2:2023-03-15_10-20-29Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F64232.jpgA9F64232.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1797.910011
20DFF8CF3-158D-4701-BCC0-ABCDC38DD42153AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60N, 2 pole, 20 A, D curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F752205621197.943.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 2P Number of protected poles: 2 [In] rated current: 20 A Network type: DC/AC Trip unit technology: Thermal-magnetic Curve code: D Breaking capacity: - 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 36 kA Icu at 12. 60 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 - 10 kA Icu at 380. 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 20 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 36 kA Icu at 100. 133 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - EN 60898-1 - IEC 60947-2 - IEC 60898-1 - EN 60947-2ACTI920A2P10KAD download-catalogue/schneider/distribution/a9f75220-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F75220_Image-StopMotion/20200616T0147/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F75220.jpgSA9F75220.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11041.690011
2132F47E1-2A57-40CB-BA4D-DB275BB6AAE953AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60a, 3P, 20 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F643205261106.6333.0000
Over-voltage resistance by high level of industrial performances conception (pollution degree, rated impulse withstand voltage and insulation voltage)
High performance limitation
Fast closing independent of the speed of actuation of the toggle
Remote indication, open/close/tripped, by optional auxiliary contacts
Top or bottom electrical feeding
Class 2 front face
Promises absolute protection against electric shocks
iC60a circuit breakers are multi-standard circuit breakers which combine the following functions
Circuit protection against short-circuit currents
Circuit protection against overload currents
Suitable for industrial isolation according to IEC/EN 60947-2, standard
Colour: White, black and green Poles: 2P Breaking capacity: 6kA Rated voltage: 220/415V Curve code: C-Curve Technical document: DownloadACTI920A3P6KACdownload-catalogue/schneider/distribution/a9f64320-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64320_Schneider_Acti9/20210205T1447/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F64320.jpgA9F64320.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1962.290011
213471E84-C2E2-41C0-8B37-3596F2E8A96753AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60N, 2 pole, 2 A, D curve, 6000 A (IEC 60898-1), 50 kA (IEC 60947-2)S/A9F752025601471.07Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 2P Number of protected poles: 2 [In] rated current: 2 A Network type: DC/AC Trip unit technology: Thermal-magnetic Curve code: D Breaking capacity: - 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 50 kA Icu at 12. 60 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 50 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 50 kA Icu at 100. 133 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 50 kA Icu at 380. 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - IEC 60898-1 - EN 60898-1 - EN 60947-2 - IEC 60947-2ACTI92A2P10KAD download-catalogue/schneider/distribution/a9f75202-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F75202_Image-StopMotion/20200321T1408/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F75202.jpgSA9F75202.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11279.190011
21F271ABE-098F-4127-AEC6-838E2211FD9053AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60N, 1 pole, 16 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F77116567313.058.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 1P Number of protected poles: 1 [In] rated current: 16 A Network type: DC/AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: - 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 10 kA Icu at 60. 72 V DC conforming to EN/IEC 60947-2 - 15 kA Icu at 12. 60 V DC conforming to EN/IEC 60947-2 - 10 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 36 kA Icu at 12. 60 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 20 kA Icu at 100. 133 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - IEC 60898-1 - EN 60898-1 - EN 60947-2 - IEC 60947-2 Quality labels: NFACTI916A1P10KAC download-catalogue/schneider/distribution/a9f77116-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F77116_Image-StopMotion/20200616T0326/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F77116.jpgSA9F77116.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1272.220011
222E38FFD-14F7-4FC7-BB7D-0FFC26F7E0F953AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 2P, 32 A, C curve, 3 kAS/EZ9F53232586171.4536.0000Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 2P Number of protected poles: 2 [In] rated current: 32 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY932A2P3KAC download-catalogue/schneider/distribution/ez9f53232-document.pdf1|2024-09-19:04:002:2023-03-01_06-01-59|2:2023-03-01_06-02-13|1:2023-03-06_17-28-58|1:2023-03-06_17-29-02|1:2023-03-06_17-29-08|1:2023-03-06_17-29-12|1:2023-03-06_17-29-20|1:2023-03-06_17-29-25|1:2023-03-06_17-29-31|13:2023-04-26_22-05-45|13:2023-04-26_22-05-55|1:2023-07-15_22-25-39|1:2023-07-15_22-25-56|1:2023-09-06_21-59-40|1:2023-09-06_21-59-48|1:2023-09-06_21-59-55|1:2023-09-06_22-00-06Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53232.jpgSEZ9F53232.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1149.090011
225622D30-6853-4942-8E0F-66D0BE24F25C53AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 3P, 63 A, C curve, 3 kAS/EZ9F53363596246.153.0000Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 3P Number of protected poles: 3 [In] rated current: 63 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY963A3P3KAC download-catalogue/schneider/distribution/ez9f53363-document.pdf1|2024-09-19:04:003:2023-04-14_19-20-51|3:2023-04-14_19-20-54Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53363.jpgSEZ9F53363.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1214.040011
228C0E37A-EF35-4CCE-824B-5F57FF1AA4AA53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60a, 2P, 25 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F64225518917.616.0000
Over-voltage resistance by high level of industrial performances conception (pollution degree, rated impulse withstand voltage and insulation voltage)
High performance limitation
Fast closing independent of the speed of actuation of the toggle
Remote indication, open/close/tripped, by optional auxiliary contacts
Top or bottom electrical feeding
Class 2 front face
Promises absolute protection against electric shocks
iC60a circuit breakers are multi-standard circuit breakers which combine the following functions
Circuit protection against short-circuit currents
Circuit protection against overload currents
Suitable for industrial isolation according to IEC/EN 60947-2, standard
Colour: White, black and green Poles: 2P Breaking capacity: 6kA Rated voltage: 220/415V Curve code: C-Curve Technical document: DownloadACTI925A2P6KACdownload-catalogue/schneider/distribution/a9f64225-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64225_Schneider_Acti9/20210217T0659/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F64225.jpgA9F64225.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1797.910011
2290F1EF5-8818-47D7-BD5E-79A6D4564CB953AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60N, 3 pole, 25 A, D curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F753255391812.4615.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 3P Number of protected poles: 3 [In] rated current: 25 A Network type: AC DC Trip unit technology: Thermal-magnetic Curve code: DACTI925A3P10KADdownload-catalogue/schneider/distribution/a9f75325-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F75325_Image-StopMotion/20200616T0147/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F75325.jpgA9F75325.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11576.050011
22C0DAB58-5598-4BAF-A481-53A99B6B63A153AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60N, 3 pole, 50 A, D curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F753505641843.433.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 3P Number of protected poles: 3 [In] rated current: 50 A Network type: DC/AC Trip unit technology: Thermal-magnetic Curve code: D Breaking capacity: - 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 36 kA Icu at 12. 60 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 10 kA Icu at 380. 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 20 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 36 kA Icu at 100. 133 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 10 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - EN 60898-1 - IEC 60898-1 - IEC 60947-2 - EN 60947-2ACTI950A3P10KAD download-catalogue/schneider/distribution/a9f75350-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F75350_Image-StopMotion/20200616T0147/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F75350.jpgSA9F75350.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11602.980011
230E8F612-EFFC-427F-A0D1-E4868D434DC453AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 C120a, 3P, 100 A, D curve, 5 kA (IEC 60947-2)S/A9N607245773038.984.0000Range of product: C120 Range: Acti 9 Product name: C120 Product or component type: Miniature circuit-breaker Device short name: C120a Device application: Distribution Poles description: 3P Number of protected poles: 3 [In] rated current: 100 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: D Breaking capacity: 5 kA Icu at 230. 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 Suitability for isolation: Yes conforming to EN/IEC 60947-2ACTI9100A3P5KAD download-catalogue/schneider/distribution/a9n60724-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9N60724.jpgSA9N60724.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric12642.590011
23F165318-2ABD-4F96-93B9-F925907CB5CF53AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 3P, 32 A, C curve, 3 kAS/EZ9F53332593246.1523.0000Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 3P Number of protected poles: 3 [In] rated current: 32 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY932A3P3KAC download-catalogue/schneider/distribution/ez9f53332-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53332.jpgSEZ9F53332.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1214.040011
241BCDC4C-05B1-44D3-8DFD-3C97E93D64C553AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 2P, 50 A, C curve, 3 kAS/EZ9F53250587171.458.0000Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 2P Number of protected poles: 2 [In] rated current: 50 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY950A2P3KAC download-catalogue/schneider/distribution/ez9f53250-document.pdf1|2024-09-19:04:001:2023-03-06_17-28-57|1:2023-03-06_17-29-01|1:2023-03-06_17-29-08|1:2023-03-06_17-29-11|1:2023-03-06_17-29-20|1:2023-03-06_17-29-24|1:2023-03-06_17-29-30Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53250.jpgSEZ9F53250.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1149.090011
24A5990CD-3FC7-456C-9756-016DC2F706F953AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60a, 3P, 10 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F643105241106.6327.0000
Over-voltage resistance by high level of industrial performances conception (pollution degree, rated impulse withstand voltage and insulation voltage)
High performance limitation
Fast closing independent of the speed of actuation of the toggle
Remote indication, open/close/tripped, by optional auxiliary contacts
Top or bottom electrical feeding
Class 2 front face
Promises absolute protection against electric shocks
iC60a circuit breakers are multi-standard circuit breakers which combine the following functions
Circuit protection against short-circuit currents
Circuit protection against overload currents
Suitable for industrial isolation according to IEC/EN 60947-2, standard
Colour: White, black and green Poles: 2P Breaking capacity: 6kA Rated voltage: 220/415V Curve code: C-Curve Technical document: DownloadACTI910A3P6KACdownload-catalogue/schneider/distribution/a9f64310-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64310_Schneider_Acti9/20210205T1447/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F64310.jpgA9F64310.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1962.290011
24B94E344-4643-42C3-8A9D-DD39D668E42353AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60N, 3 pole, 16 A, D curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F753165371793.862.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 3P Number of protected poles: 3 [In] rated current: 16 A Network type: AC DC Trip unit technology: Thermal-magnetic Curve code: DACTI916A3P10KADdownload-catalogue/schneider/distribution/a9f75316-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F75316_Image-StopMotion/20200616T0147/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F75316.jpgA9F75316.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11559.880011
24E067475-C740-4795-A3E1-4E2A4D38D5EA53AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60a, 4P, 40 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F644405591237.273.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60a Poles description: 4P Number of protected poles: 4 [In] rated current: 40 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: - 4500 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 10 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 6 kA Icu at 380. 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - EN 60898-1 - IEC 60898-1 - EN 60947-2 - IEC 60947-2ACTI940A4P6KAC download-catalogue/schneider/distribution/a9f64440-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64440_Schneider_Acti9/20210205T1447/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F64440.jpgSA9F64440.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11075.890011
24F21A2DC-6378-4CFF-995B-4012CAC9DC7853AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60N, 1P, 20 A, D curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F75120533360.0112.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 1P Number of protected poles: 1 [In] rated current: 20 A Network type: DC AC Trip unit technology: Thermal-magnetic Curve code: DACTI920A1P10KADdownload-catalogue/schneider/distribution/a9f75120-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F75120_Image-StopMotion/20200616T0056/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F75120.jpgA9F75120.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1313.050011
2518FE81C-0FEF-4B19-8F7A-E774662F0AA053AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 3P, 25 A, C curve, 3 kAS/EZ9F53325592246.159.0000Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 3P Number of protected poles: 3 [In] rated current: 25 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY925A3P3KAC download-catalogue/schneider/distribution/ez9f53325-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53325.jpgSEZ9F53325.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1214.040011
253316C51-FFFD-42D4-9CE2-5C803E203CFB53AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 3P, 6 A, C curve, 3 kAS/EZ9F53306589246.154.0000Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 3P Number of protected poles: 3 [In] rated current: 6 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY96A3P3KAC download-catalogue/schneider/distribution/ez9f53306-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53306.jpgSEZ9F53306.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1214.040011
2543193C5-0301-434F-8828-371D4B421F5F53AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 2P, 20 A, C curve, 3 kAS/EZ9F53220585171.4515.0000Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 2P Number of protected poles: 2 [In] rated current: 20 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY920A2P3KAC download-catalogue/schneider/distribution/ez9f53220-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53220.jpgSEZ9F53220.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1149.090011
255CDA48D-31FC-4369-ACB3-4F09C46AF44653AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60N, 1P, 6 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F77106565313.054.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 1P Number of protected poles: 1 [In] rated current: 6 A Network type: AC/DC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: - 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 10 kA Icu at 60. 72 V DC conforming to EN/IEC 60947-2 - 15 kA Icu at 12. 60 V DC conforming to EN/IEC 60947-2 - 10 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 36 kA Icu at 12. 60 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 20 kA Icu at 100. 133 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - IEC 60947-2 - IEC 60898-1 - EN 60898-1 - EN 60947-2 Quality labels: NFACTI96A1P10KAC download-catalogue/schneider/distribution/a9f77106-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F77106_Image-StopMotion/20200616T0326/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F77106.jpgSA9F77106.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1272.220011
25B076CDE-43F7-46E7-B877-8F99EE3385CA53AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 1P, 25 A, C curve, 3 kAS/EZ9F5312558070.1858.0000Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 3P Number of protected poles: 3 [In] rated current: 25 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY925A1P3KAC download-catalogue/schneider/distribution/ez9f53325-document.pdf1|2024-09-19:04:001:2022-11-16_09-46-33|1:2022-11-16_09-46-40|2:2023-07-24_06-56-58|2:2023-07-24_06-57-08|2:2023-07-24_06-57-20|2:2023-07-24_06-57-22|2:2023-07-24_06-57-25|2:2023-07-24_06-57-29|1:2023-09-06_21-59-40|1:2023-09-06_21-59-48|1:2023-09-06_21-59-55|1:2023-09-06_22-00-07Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53125.jpgSEZ9F53125.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric161.030011
26002D201-837E-4931-B897-2DC74EAA533253AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60N, 2 pole, 6 A, D curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F752065361197.94Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 2P Number of protected poles: 2 [In] rated current: 6 A Network type: DC AC Trip unit technology: Thermal-magnetic Curve code: DACTI96A2P10KADdownload-catalogue/schneider/distribution/a9f75206-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F75206_Image-StopMotion/20200616T0147/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F75206.jpgA9F75206.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11041.690011
262DAEF4C-15C0-4545-8944-C27269C3CB7353AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60a, 3P, 40 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F643405291212.3627.0000
Over-voltage resistance by high level of industrial performances conception (pollution degree, rated impulse withstand voltage and insulation voltage)
High performance limitation
Fast closing independent of the speed of actuation of the toggle
Remote indication, open/close/tripped, by optional auxiliary contacts
Top or bottom electrical feeding
Class 2 front face
Promises absolute protection against electric shocks
iC60a circuit breakers are multi-standard circuit breakers which combine the following functions
Circuit protection against short-circuit currents
Circuit protection against overload currents
Suitable for industrial isolation according to IEC/EN 60947-2, standard
Colour: White, black and green Poles: 3P Breaking capacity: 6kA Rated voltage: 220/415V Curve code: C-Curve Technical document: DownloadACTI940A3P6KACdownload-catalogue/schneider/distribution/a9f64340-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64340_Schneider_Acti9/20210205T1447/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F64340.jpgA9F64340.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11054.230011
26746780C-1AD1-4E2B-9459-9FA172ED5E1253AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 3P, 40 A, C curve, 3 kAS/EZ9F53340594246.1517.0000Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 3P Number of protected poles: 3 [In] rated current: 40 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY940A3P3KAC download-catalogue/schneider/distribution/ez9f53340-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53340.jpgSEZ9F53340.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1214.040011
26916D4B5-3E8A-4C5A-A618-A0AE8907563C53AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60N, 3 pole, 63 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F773635731602.989.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 3P Number of protected poles: 3 [In] rated current: 63 A Network type: AC/DC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: - 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 36 kA Icu at 12. 60 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 10 kA Icu at 380. 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 20 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 36 kA Icu at 100. 133 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 10 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: EN 60947-2 - EN 60898-1 - IEC 60947-2 - IEC 60898-1 Quality labels: NFACTI963A3P10KAC download-catalogue/schneider/distribution/a9f77363-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F77363_Image-StopMotion/20200616T0436/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F77363.jpgSA9F77363.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11393.90011
26DEB9D02-70C5-40F4-B774-A6767F50B0B353AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60a, 4P, 32 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F644325581237.291.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60a Poles description: 4P Number of protected poles: 4 [In] rated current: 32 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: - 4500 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 10 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 6 kA Icu at 380. 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - IEC 60947-2 - EN 60947-2 - IEC 60898-1 - EN 60898-1ACTI932A4P6KAC download-catalogue/schneider/distribution/a9f64432-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64432_Schneider_Acti9/20210205T1447/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F64432.jpgSA9F64432.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11075.90011
26E0254D3-E7DF-4E98-88F6-9F74B6C600D953AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60a, 2P, 3 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F64203555983.97Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60a Poles description: 2P Number of protected poles: 2 [In] rated current: 3 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: - 4500 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 10 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 6 kA Icu at 380. 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - IEC 60898-1 - IEC 60947-2 - EN 60898-1 - EN 60947-2ACTI93A2P6KAC download-catalogue/schneider/distribution/a9f64203-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64203_Schneider_Acti9/20210217T0659/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F64203.jpgSA9F64203.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1855.630011
274B807AC-3E48-4856-ADFF-87E99227EDFF53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60a, 2 pole, 6 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F64206514801.3146.0000
Over-voltage resistance by high level of industrial performances conception (pollution degree, rated impulse withstand voltage and insulation voltage)
High performance limitation
Fast closing independent of the speed of actuation of the toggle
Remote indication, open/close/tripped, by optional auxiliary contacts
Top or bottom electrical feeding
Class 2 front face
Promises absolute protection against electric shocks
iC60a circuit breakers are multi-standard circuit breakers which combine the following functions
Circuit protection against short-circuit currents
Circuit protection against overload currents
Suitable for industrial isolation according to IEC/EN 60947-2, standard
Colour: White, black and green Poles: 2P Breaking capacity: 6kA Rated voltage: 220/415V Curve code: C-Curve Technical document: DownloadACTI96A2P6KACdownload-catalogue/schneider/distribution/a9f64206-act-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64206_Schneider_Acti9/20210203T0553/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F64206.jpgA9F64206.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1696.790011
277CC14FD-5380-4731-8B3E-98858BAE567153AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60a, 3P, 6 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F643065231106.635.0000
Over-voltage resistance by high level of industrial performances conception (pollution degree, rated impulse withstand voltage and insulation voltage)
High performance limitation
Fast closing independent of the speed of actuation of the toggle
Remote indication, open/close/tripped, by optional auxiliary contacts
Top or bottom electrical feeding
Class 2 front face
Promises absolute protection against electric shocks
iC60a circuit breakers are multi-standard circuit breakers which combine the following functions
Circuit protection against short-circuit currents
Circuit protection against overload currents
Suitable for industrial isolation according to IEC/EN 60947-2, standard
Colour: White, black and green Poles: 2P Breaking capacity: 6kA Rated voltage: 220/415V Curve code: C-Curve Technical document: DownloadACTI96A3P6KACdownload-catalogue/schneider/distribution/a9f64306-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64306_Schneider_Acti9/20210203T0553/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F64306.jpgA9F64306.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1962.290011
27A1FC6AC-DD05-4146-87BA-AB592DF5F7FE53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60N, 1P, 32 A, D curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F75132535372.397.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 1P Number of protected poles: 1 [In] rated current: 32 A Network type: AC DC Trip unit technology: Thermal-magnetic Curve code: DACTI932A1P10KADdownload-catalogue/schneider/distribution/a9f75132-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F75132_Image-StopMotion/20200616T0147/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F75132.jpgA9F75132.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1323.820011
27B8641AC-E6D7-4669-B559-1CB83374F75953AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 2P, 16 A, C curve, 3 kAS/EZ9F53216584171.45Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 2P Number of protected poles: 2 [In] rated current: 16 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY916A2P3KAC download-catalogue/schneider/distribution/ez9f53216-document.pdf1|2024-09-19:04:002:2023-02-05_23-19-24|2:2023-02-05_23-19-29|2:2023-02-05_23-19-43|6:2023-03-24_10-32-48Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53216.jpgSEZ9F53216.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1149.090011
27C97E335-F5CF-4B1C-8E9F-846CBCD587A353AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60N, 2 pole, 63 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F772635711268.46Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 2P Number of protected poles: 2 [In] rated current: 63 A Network type: DC/AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: - 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 36 kA Icu at 12. 60 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 - 10 kA Icu at 380. 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 20 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 36 kA Icu at 100. 133 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - IEC 60947-2 - EN 60947-2 - IEC 60898-1 - EN 60898-1 Quality labels: NFACTI963A2P10KAC download-catalogue/schneider/distribution/a9f77263-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F77263_Image-StopMotion/20200616T0436/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F77263.jpgSA9F77263.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11103.010011
28A7A0938-675F-4747-BDF4-F47B36DDAA1453AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60N, 3 pole, 10 A, D curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F753105631793.8611.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 3P Number of protected poles: 3 [In] rated current: 10 A Network type: DC/AC Trip unit technology: Thermal-magnetic Curve code: D Breaking capacity: - 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 36 kA Icu at 12. 60 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 10 kA Icu at 380. 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 20 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 36 kA Icu at 100. 133 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 10 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - EN 60898-1 - IEC 60947-2 - IEC 60898-1 - EN 60947-2ACTI910A3P10KAD download-catalogue/schneider/distribution/a9f75310-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F75310_Image-StopMotion/20200616T0147/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F75310.jpgSA9F75310.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11559.880011
28AFE0BD6-1592-4E33-916E-F67906B84C3053AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60a, 2P, 40 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F64240520917.618.0000
Over-voltage resistance by high level of industrial performances conception (pollution degree, rated impulse withstand voltage and insulation voltage)
High performance limitation
Fast closing independent of the speed of actuation of the toggle
Remote indication, open/close/tripped, by optional auxiliary contacts
Top or bottom electrical feeding
Class 2 front face
Promises absolute protection against electric shocks
iC60a circuit breakers are multi-standard circuit breakers which combine the following functions
Circuit protection against short-circuit currents
Circuit protection against overload currents
Suitable for industrial isolation according to IEC/EN 60947-2, standard
Colour: White, black and green Poles: 2P Breaking capacity: 6kA Rated voltage: 220/415V Curve code: C-Curve Technical document: DownloadACTI940A2P6KACdownload-catalogue/schneider/distribution/a9f64240-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64240_Schneider_Acti9/20210217T0659/3603dobject>1:2023-02-02_13-47-07|1:2023-02-02_13-47-15|1:2023-02-02_13-47-22|1:2023-02-02_13-47-27|1:2023-02-02_13-47-39|1:2023-02-02_13-47-44|1:2023-02-02_13-47-59Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F64240.jpgA9F64240.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1797.910011
292BDFF78-2CD3-4525-95C9-65D758350C6053AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60N, 2 pole, 16 A, D curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F752165611197.94Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 2P Number of protected poles: 2 [In] rated current: 16 A Network type: DC/AC Trip unit technology: Thermal-magnetic Curve code: D Breaking capacity: - 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 36 kA Icu at 12. 60 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 - 10 kA Icu at 380. 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 20 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 36 kA Icu at 100. 133 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - EN 60947-2 - IEC 60898-1 - IEC 60947-2 - EN 60898-1ACTI916A2P10KAD download-catalogue/schneider/distribution/a9f75216-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F75216_Image-StopMotion/20200616T0147/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F77216.jpgSA9F77216.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11041.690011
29AD74A54-3E56-4756-ABD9-C7F4EA1EA8F453AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 1P, 40 A, C curve, 3 kAS/EZ9F5314058170.1846.0000Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 1P Number of protected poles: 1 [In] rated current: 40 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 230 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY940A1P3KAC download-catalogue/schneider/distribution/ez9f53140-document.pdf1|2024-09-19:04:002:2022-11-16_09-46-31|2:2022-11-16_09-46-39|12:2023-02-12_11-37-23|12:2023-02-12_11-37-36|12:2023-02-12_11-37-47|12:2023-02-12_11-38-00|12:2023-02-12_11-38-06|3:2023-05-07_18-08-36|3:2023-05-07_18-08-44|3:2023-05-07_18-08-59|3:2023-05-07_18-09-14|3:2023-05-07_18-09-18|3:2023-05-07_18-09-33|3:2023-05-07_18-09-37|1:2023-06-04_12-54-28|1:2023-06-04_12-54-35|1:2023-06-04_12-54-40|1:2023-06-04_12-54-51|1:2023-06-04_12-54-58|1:2023-06-04_12-55-09|1:2023-06-04_12-55-13Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53140.jpgSEZ9F53140.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric161.030011
29CB6CCE4-2BFC-4FF6-A605-37BA7DC5637C53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60a, 2P, 50 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F64250521975.672.0000
Over-voltage resistance by high level of industrial performances conception (pollution degree, rated impulse withstand voltage and insulation voltage)
High performance limitation
Fast closing independent of the speed of actuation of the toggle
Remote indication, open/close/tripped, by optional auxiliary contacts
Top or bottom electrical feeding
Class 2 front face
Promises absolute protection against electric shocks
iC60a circuit breakers are multi-standard circuit breakers which combine the following functions
Circuit protection against short-circuit currents
Circuit protection against overload currents
Suitable for industrial isolation according to IEC/EN 60947-2, standard
Colour: White, black and green Poles: 2P Breaking capacity: 6kA Rated voltage: 220/415V Curve code: C-Curve Technical document: DownloadACTI950A2P6KACdownload-catalogue/schneider/distribution/a9f64250-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64250_Schneider_Acti9/20210203T0553/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F64250.jpgA9F64250.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1848.410011
29EA72BF6-1B2D-4899-9C01-E1D4D5E755E653AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60a, 3P, 25 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F643255271212.3618.0000
Over-voltage resistance by high level of industrial performances conception (pollution degree, rated impulse withstand voltage and insulation voltage)
High performance limitation
Fast closing independent of the speed of actuation of the toggle
Remote indication, open/close/tripped, by optional auxiliary contacts
Top or bottom electrical feeding
Class 2 front face
Promises absolute protection against electric shocks
iC60a circuit breakers are multi-standard circuit breakers which combine the following functions
Circuit protection against short-circuit currents
Circuit protection against overload currents
Suitable for industrial isolation according to IEC/EN 60947-2, standard
Colour: White, black and green Poles: 2P Breaking capacity: 6kA Rated voltage: 220/415V Curve code: C-Curve Technical document: DownloadACTI925A3P6KACdownload-catalogue/schneider/distribution/a9f64325-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64325_Schneider_Acti9/20210205T1447/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F64325.jpgA9F64325.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11054.230011
2A07EB082-5FF8-47DD-AB56-EDD82FFD0B5253AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60a, 3P, 2 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F643025561172.314.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60a Poles description: 3P Number of protected poles: 3 [In] rated current: 2 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: - 4500 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 10 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 6 kA Icu at 380. 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - EN 60947-2 - IEC 60947-2 - IEC 60898-1 - EN 60898-1ACTI92A3P6KAC download-catalogue/schneider/distribution/a9f64302-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64302_Schneider_Acti9/20210217T0659/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F64302.jpgSA9F64302.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11019.40011
2A1FC2DCE-8939-49A2-A47C-8F261272D77253AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60N, 3 pole, 63 A, D curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F753635421843.437.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 3P Number of protected poles: 3 [In] rated current: 63 A Network type: AC DC Trip unit technology: Thermal-magnetic Curve code: DACTI963A3P10KADdownload-catalogue/schneider/distribution/a9f75363-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F75363_Image-StopMotion/20200616T0147/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F75363.jpgA9F75363.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11602.980011
2A22C1309-1371-4EF2-AD55-5AF5D262F4B653AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 C120a, 1P, 100 A, C curve, 5 kA (IEC 60947-2)S/A9N60709575572.95-1.0000Range of product: C120 Range: Acti 9 Product name: C120 Product or component type: Miniature circuit-breaker Device short name: C120a Device application: Distribution Poles description: 1P Number of protected poles: 1 [In] rated current: 100 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 5 kA Icu at 230. 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 Suitability for isolation: Yes conforming to EN/IEC 60947-2ACTI9100A1P5KAC download-catalogue/schneider/distribution/a9n60709-document.pdf1|2024-09-19:04:002:2023-02-03_11-00-38Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9N60709.jpgSA9N60709.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1498.220011
2A7F3E5FB-1AC7-46F6-BF4B-5DD64BAB3DAB53AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60N, 1 pole, 10 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F77110566313.0514.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 1P Number of protected poles: 1 [In] rated current: 10 A Network type: DC/AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: - 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 10 kA Icu at 60. 72 V DC conforming to EN/IEC 60947-2 - 15 kA Icu at 12. 60 V DC conforming to EN/IEC 60947-2 - 10 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 36 kA Icu at 12. 60 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 20 kA Icu at 100. 133 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - EN 60898-1 - IEC 60898-1 - IEC 60947-2 - EN 60947-2 Quality labels: NFACTI910A1P10KAC download-catalogue/schneider/distribution/a9f77110-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F77110_Image-StopMotion/20200616T0326/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F77110.jpgSA9F77110.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1272.220011
2A953BED0-D744-4CEE-A34F-6999F040AECA53AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60a, 4P, 25 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F644255571237.2912.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60a Poles description: 4P Number of protected poles: 4 [In] rated current: 25 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: - 4500 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 10 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 6 kA Icu at 380. 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - IEC 60898-1 - EN 60947-2 - IEC 60947-2 - EN 60898-1ACTI925A4P6KAC download-catalogue/schneider/distribution/a9f64425-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64425_Schneider_Acti9/20210205T1447/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F64425.jpgSA9F64425.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11075.90011
2B148CE46-BFA3-4E10-A14D-F6783C9D996F53AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 3P, 50 A, C curve, 3 kAS/EZ9F53350595246.159.0000Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 3P Number of protected poles: 3 [In] rated current: 50 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY950A3P3KAC download-catalogue/schneider/distribution/ez9f53350-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53350.jpgSEZ9F53350.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1214.040011
2B821D322-AA40-43C1-8B5D-7F7683C5C5FB53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 C120N, 3P, 100 A, C curve, 10 kA (IEC 60947-2)S/A9N607385473371.9332.0000Range of product: C120 Range: Acti 9 Product name: C120 Product or component type: Miniature circuit-breaker Device short name: C120N Device application: Distribution Poles description: 3P Number of protected poles: 3 [In] rated current: 100A Network type: AC Trip unit technology: Thermal-magnetic Curve code: CACTI9100A3P10KACdownload-catalogue/schneider/distribution/a9n60738-acti-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741A9N60738.jpgA9N60738.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric12932.110011
2B86B456E-620B-4ED4-8D87-A6C7903760F253AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60N, 3 pole, 16 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F773165721559.882.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 3P Number of protected poles: 3 [In] rated current: 16 A Network type: AC/DC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: - 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 36 kA Icu at 12. 60 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 10 kA Icu at 380. 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 20 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 36 kA Icu at 100. 133 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 10 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - IEC 60898-1 - IEC 60947-2 - EN 60898-1 - EN 60947-2 Quality labels: NFACTI916A3P10KAC download-catalogue/schneider/distribution/a9f77316-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F77316_Image-StopMotion/20200616T0436/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F77316.jpgSA9F77316.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11356.420011
2B86F6CED-B66E-49C3-89B0-EF67B7E4177A53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 C120a, 3P, 80 A, C curve, 5 kA (IEC 60947-2)S/A9N607145452307.3510.0000Range of product: C120 Range: Acti 9 Product name: C120 Product or component type: Miniature circuit-breaker Device short name: C120N Device application: Distribution Poles description: 3P Number of protected poles: 3 [In] rated current: 125 A at 30 °C Network type: AC Trip unit technology: Thermal-magnetic Curve code: CACTI980A3P5KACdownload-catalogue/schneider/distribution/a9n60714-acti-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741A9N60714.jpgA9N60714.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric12006.390011
2BADCAAFC-3E04-45FF-850A-FD0366767ECB53AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 3P, 20 A, C curve, 3 kAS/EZ9F53320591246.1517.0000Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 3P Number of protected poles: 3 [In] rated current: 20 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY920A3P3KAC download-catalogue/schneider/distribution/ez9f53320-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53320.jpgSEZ9F53320.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1214.040011
2BD277E99-B1F1-4C57-82ED-94E6AEB6CC5253AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60N, 2 pole, 16 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F772165701041.75Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 2P Number of protected poles: 2 [In] rated current: 16 A Network type: AC/DC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: - 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 36 kA Icu at 12. 60 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 - 10 kA Icu at 380. 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 20 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 36 kA Icu at 100. 133 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - IEC 60898-1 - EN 60947-2 - EN 60898-1 - IEC 60947-2 Quality labels: NFACTI916A2P10KAC download-catalogue/schneider/distribution/a9f77216-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F77216_Image-StopMotion/20200616T0326/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F77216.jpgSA9F77216.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1905.870011
2C01D1D69-61C9-4E66-89B2-62D6990A599B53AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 1P, 63 A, C curve, 3 kAS/EZ9F5316358270.1815.0000Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 1P Number of protected poles: 1 [In] rated current: 63 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 230 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY963A1P3KAC download-catalogue/schneider/distribution/ez9f53163-document.pdf1|2024-09-19:04:001:2022-11-16_09-46-32|1:2022-11-16_09-46-39|1:2023-05-07_18-08-35Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53163.jpgSEZ9F53163.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric161.030011
2C17D576C-ED0E-4B2C-9925-4270ABC99D6D53AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 2P, 63 A, C curve, 3 kAS/EZ9F53263588171.4532.0000Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 2P Number of protected poles: 2 [In] rated current: 63 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY963A2P3KAC download-catalogue/schneider/distribution/ez9f53263-document.pdf1|2024-09-19:04:002:2023-05-07_18-08-37|2:2023-05-07_18-08-45|2:2023-05-07_18-09-00|2:2023-05-07_18-09-15|2:2023-05-07_18-09-19|2:2023-05-07_18-09-34|2:2023-05-07_18-09-38|1:2023-05-08_13-51-24|1:2023-05-08_13-51-36|1:2023-05-08_13-51-46|1:2023-07-08_16-39-43|1:2023-07-08_16-39-53|1:2023-07-19_10-57-21|1:2023-07-19_10-57-31Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53263.jpgSEZ9F53263.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1149.090011
2C3CD6985-F41F-4145-8B91-578675F9D0B953AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 3P, 16 A, C curve, 3 kAS/EZ9F53316590246.152.0000Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 3P Number of protected poles: 3 [In] rated current: 16 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY916A3P3KAC download-catalogue/schneider/distribution/ez9f53316-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53316.jpgSEZ9F53316.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1214.040011
2C3D47751-F5F7-471F-B7AB-1455FACD699353AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60N, 3 pole, 20 A, D curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F753205381793.864.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 3P Number of protected poles: 3 [In] rated current: 20 A Network type: AC DC Trip unit technology: Thermal-magnetic Curve code: DACTI920A3P10KADdownload-catalogue/schneider/distribution/a9f75320-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F75320_Image-StopMotion/20200616T0147/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F75320.jpgA9F75320.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11559.880011
2CE846F02-3C3D-4610-9E9F-421BA6FF106553AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit breaker, Easy9, 2P, 10 A, C curve, 3 kAS/EZ9F53210583171.45Range: Easy9 Device application: Distribution Product or component type: Miniature circuit-breaker Device short name: Easy9 MCB Poles: 2P Number of protected poles: 2 [In] rated current: 10 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category: Category A Suitability for isolation: Yes conforming to SANS 60947-2EASY910A2P3KAC download-catalogue/schneider/distribution/ez9f53210-document.pdf1|2024-09-19:04:0015:2023-02-27_14-39-06Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SEZ9F53210.jpgSEZ9F53210.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1149.090011
2CFA258A8-886A-428E-91B7-45C40E9422C953AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 C120a, 3P, 100 A, C curve, 5 kA (IEC 60947-2)S/A9N607155462814.458.0000Range of product: C120 Range: Acti 9 Product name: C120 Product or component type: Miniature circuit-breaker Device short name: C120a Device application: Distribution Poles description: 3P Number of protected poles: 3 [In] rated current: 100 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: CACTI9100A3P5KACdownload-catalogue/schneider/distribution/a9n60715-acti-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741A9N60715.jpgA9N60715.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric12447.350011
2D35B53EF-3F72-4134-8906-D6A317A01DB353AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 C120a, 1P, 80 A, C curve, 5 kA (IEC 60947-2)S/A9N60708574491.693.0000Range of product: C120 Range: Acti 9 Product name: C120 Product or component type: Miniature circuit-breaker Device short name: C120a Device application: Distribution Poles description: 1P Number of protected poles: 1 [In] rated current: 80 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: 5 kA Icu at 230. 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 Suitability for isolation: Yes conforming to EN/IEC 60947-2ACTI980A1P5KAC download-catalogue/schneider/distribution/a9n60708-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9N60708.jpgSA9N60708.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1427.560011
2D465EABF-23A4-45C8-9200-A9EAB41B1B2853AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60N, 2 pole, 6 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F772065681041.7513.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 2P Number of protected poles: 2 [In] rated current: 6 A Network type: DC/AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: - 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 36 kA Icu at 12. 60 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 - 10 kA Icu at 380. 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 20 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 36 kA Icu at 100. 133 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - EN 60898-1 - EN 60947-2 - IEC 60947-2 - IEC 60898-1 Quality labels: NFACTI96A2P10KAC download-catalogue/schneider/distribution/a9f77206-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F77206_Image-StopMotion/20200616T0326/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F77206.jpgSA9F77206.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1905.870011
2D5D9D030-165F-48F6-83FF-F6FC480D219C53AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 C120N, 2P, 100 A, C curve, 10 kA (IEC 60947-2)S/A9N607345782067.35.0000Range of product: C120 Range: Acti 9 Product name: C120 Product or component type: Miniature circuit-breaker Device short name: C120N Device application: Distribution Poles description: 2P Number of protected poles: 2 [In] rated current: 100 A Network type: AC/DC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: - 10 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2 - 10 kA Icu at 230. 400 V AC 50/60 Hz conforming to EN/IEC 60947-2ACTI9100A2P10KAC download-catalogue/schneider/distribution/a9n60734-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9N60734.jpgSA9N60734.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11797.650011
2D69240F2-C174-4D35-A98C-C4236FCCD54153AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60a, 1P, 50 A, C curve, 4500 A (IEC 60898-1), 6 kA (IEC 60947-2)S/A9F64150554288.66.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60a Poles description: 1P Number of protected poles: 1 [In] rated current: 50 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: - 4500 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 6 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - IEC 60898-1 - EN 60898-1 - IEC 60947-2 - EN 60947-2ACTI950A1P6KAC download-catalogue/schneider/distribution/a9f64150-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F64150_Schneider_Acti9/20210217T0659/3603dobject>1:2022-11-16_09-46-34|1:2022-11-16_09-46-40|5:2023-07-24_06-56-56|5:2023-07-24_06-57-05|5:2023-07-24_06-57-16|5:2023-07-24_06-57-18Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F64150.jpgSA9F64150.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1250.960011
2DAB32A85-B4CE-4D35-B821-4C7AEC3CA12053AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60N, 3 pole, 32 A, D curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F753325401812.4624.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 3P Number of protected poles: 3 [In] rated current: 32 A Network type: AC DC Trip unit technology: Thermal-magnetic Curve code: DACTI932A3P10KADdownload-catalogue/schneider/distribution/a9f75332-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F75332_Image-StopMotion/20200616T0147/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F75332.jpgA9F75332.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11576.050011
2E73FAE8E-3AAA-4CAF-A635-8FF408A94D7153AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 C120N, 3 pole, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9N183695443771.7711.0000Range of product: C120 Range: Acti 9 Product name: C120 Product or component type: Miniature circuit-breaker Device short name: C120N Device application: Distribution Poles description: 3P Number of protected poles: 3 [In] rated current: 125 A at 30 °C Network type: AC Trip unit technology: Thermal-magnetic Curve code: CACTI9125A3P10KACdownload-catalogue/schneider/distribution/a9n18369-acti-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9N18369.jpgA9N18369.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric13279.80011
2F206C3DD-5F81-4394-8AAD-7E9694DF6B5A53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741Miniature circuit-breaker, Acti9 iC60N, 1P, 25 A, D curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F75125534333.055.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 1P Number of protected poles: 1 [In] rated current: 25 A Network type: DC AC Trip unit technology: Thermal-magnetic Curve code: DACTI925A1P10KADdownload-catalogue/schneider/distribution/a9f75125-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F75125_Image-StopMotion/20200616T0056/3603dobject>1:2023-01-27_11-58-35|1:2023-01-27_11-58-50Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9F75125.jpgA9F75125.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1289.610011
2F6638E12-E85B-4EBD-9E3E-230C71DCC9E753AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 C120a, 3P, 80 A, D curve, 5 kA (IEC 60947-2)S/A9N607235762702.183.0000Range of product: C120 Range: Acti 9 Product name: C120 Product or component type: Miniature circuit-breaker Device short name: C120a Device application: Distribution Poles description: 3P Number of protected poles: 3 [In] rated current: 80 A Network type: AC Trip unit technology: Thermal-magnetic Curve code: D Breaking capacity: 5 kA Icu at 230. 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 Suitability for isolation: Yes conforming to EN/IEC 60947-2ACTI980A3P5KAD download-catalogue/schneider/distribution/a9n60723-document.pdf1|2024-09-19:04:005:2023-01-08_18-32-13|1:2024-02-16_14-37-21Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9N60723.jpgSA9N60723.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric12349.720011
2FB0F06B5-8882-4047-9EB7-40248687397553AFDAFE-71AE-4C00-8E7C-1EBB5F5A674179F6311B-33D0-4B2B-AD0B-0F94D47627C8Miniature circuit-breaker, Acti9 iC60N, 2 pole, 10 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)S/A9F772105691041.758.0000Device application: Distribution Range: Acti 9 Product name: Acti 9 iC60 Product or component type: Miniature circuit-breaker Device short name: IC60N Poles description: 2P Number of protected poles: 2 [In] rated current: 10 A Network type: DC/AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity: - 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 - 36 kA Icu at 12. 60 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 - 10 kA Icu at 380. 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 20 kA Icu at 220. 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 - 36 kA Icu at 100. 133 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category: - Category A conforming to EN 60947-2 - Category A conforming to IEC 60947-2 Suitability for isolation: - Yes conforming to EN 60898-1 - Yes conforming to EN 60947-2 - Yes conforming to IEC 60898-1 - Yes conforming to IEC 60947-2 Standards: - EN 60947-2 - EN 60898-1 - IEC 60898-1 - IEC 60947-2 Quality labels: NFACTI910A2P10KAC download-catalogue/schneider/distribution/a9f77210-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9F77210_Image-StopMotion/20200616T0326/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker53AFDAFE-71AE-4C00-8E7C-1EBB5F5A6741SA9F77210.jpgSA9F77210.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1905.870011
20B5C2734-5E6C-4F88-BF0F-D60E7CE5C25884D1C0BD-010E-4CA7-AC74-D37D7D1A375D79F6311B-33D0-4B2B-AD0B-0F94D47627C8undervoltage release, Acti9, iMNx, voltage release, 220-240 VACS/A9A26969511674.69Range of product: Acti 9 Product or component type: Undervoltage release Device short name: IMNx [Uc] control circuit voltage: 220...240 V AC 50/60 Hz Control type: With external feeding 9 mm pitches: 2ACTI9download-catalogue/schneider/distribution/a9a26969-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker Accessories84D1C0BD-010E-4CA7-AC74-D37D7D1A375DSA9A26969.jpgSA9A26969.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11456.250011
20C0E6F8B-1E95-43FD-A706-21AEF52E220484D1C0BD-010E-4CA7-AC74-D37D7D1A375D79F6311B-33D0-4B2B-AD0B-0F94D47627C8padlocking device, Acti9, set of 10S/A9A2697052375.871.0000Range of product: Acti 9 Product or component type: Padlocking device Accessory / separate part category: Locking accessory Quantity per set: Set of 10ACTI9 download-catalogue/schneider/distribution/a9a26970-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9A26970_Image-StopMotion/20211008T1302/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker Accessories84D1C0BD-010E-4CA7-AC74-D37D7D1A375DSA9A26970.jpgSA9A26970.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1326.840011
23D8757A3-FAC7-4B4E-9803-02D037664C3E84D1C0BD-010E-4CA7-AC74-D37D7D1A375Dauxiliary contact, Acti9, iOF, 1 OC, AC/DCS/A9A26924521293.97Range of product: Acti 9 Product or component type: OC contact Device short name: IOF Signal contacts composition: 1 C/O [In] rated current: 6 A: 240 V AC - 50/60 Hz 3 A: 415 V AC - 50/60 Hz 2 A: 48 V DC 1.5 A: 60 V DC 1 A: 130 V DC 9 mm pitches: 1ACTI9download-catalogue/schneider/motor-control-and-protection/a9a26924-acti-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/A9A26924_Image-StopMotion/20200311T0941/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker Accessories36772ACD-044F-47F3-80D7-C8F501D8C53BA9A26924.jpgA9A26924.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11125.190011
25B6DF78C-B50B-4E70-BEA8-70FFFC4428AB84D1C0BD-010E-4CA7-AC74-D37D7D1A375D79F6311B-33D0-4B2B-AD0B-0F94D47627C8Rotary handle - for iC60 - black handleS/A9A27005531604.245.0000Range of product: - IID - ISW 40...125 - ISW-NA - IC60 Product or component type: Rotary handle Accessory / separate part type: Control accessories Mounting mode: - Drawout - Fixed Rotary handle padlocking: - Lockable in O position - 3 padlocks max - Padlock in OFF position Rotary handle mounting location: - Front - LateralACTI9 download-catalogue/schneider/distribution/a9a27005-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker Accessories84D1C0BD-010E-4CA7-AC74-D37D7D1A375DSA9A27005.jpgSA9A27005.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11394.990011
25E9352F2-67C7-469D-8493-5BB90F7A1B8E84D1C0BD-010E-4CA7-AC74-D37D7D1A375Dovervoltage release, Acti9, iMSU, voltage release, 230 VACS/A9A26500511153.224.0000Range of product: Acti 9 Product or component type: Overvoltage release Device short name: IMSU [Uc] control circuit voltage: 230 V AC 50/60 Hz Threshold tripping voltage: 255 V 275 V 3...15 s 300 V 1...5 s 350 V 0.25...0.75 s 400 V 0.07...0.2 s 9 mm pitches: 2ACTI9download-catalogue/schneider/distribution/a9a26500-acti-document.pdf1|2024-09-19:04:001:2022-11-16_09-46-34|1:2022-11-16_09-46-41Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker Accessories7311FFF8-1E60-4F20-9E9D-E5E2671CB9C4A9A26500.jpgA9A26500.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric11002.80011
29C09D5CF-5A6A-49C0-A7DE-E27517AD4EC084D1C0BD-010E-4CA7-AC74-D37D7D1A375D79F6311B-33D0-4B2B-AD0B-0F94D47627C8set of 10 end caps 1 Pole for Acti9S/A9XPE11054287.86Range: Acti 9 Product name: Linergy FH Product or component type: Comb busbar side cover Accessory / separate part category: Insulation accessory Poles description: 1P Quantity per set: Set of 10ACTI91Pdownload-catalogue/schneider/distribution/a9xpe110-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Miniature Circuit Breaker Accessories84D1C0BD-010E-4CA7-AC74-D37D7D1A375DSA9XPE110.jpgSA9XPE110.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\images/Schneider Electric1250.310011
20633C095-D5D2-431F-A42B-51B7D314C2187C4D9E7E-E80A-46BB-83DD-92EED2C661BDcircuit breaker ComPact NSX250F, 36 kA at 415 VAC, TMD trip unit 200 A, 3 poles 3dS/LV43163158710284.47Range: Compact Product name: Compact NSX Range of product: NSX100...250 Device short name: Compact NSX250F Product or component type: Circuit breaker Device application: Distribution Poles description: 3P Protected poles description: 3t [In] rated current: 200 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA at 240 V AC 50/60 Hz conforming to UL 508 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 480 V AC 50/60 Hz conforming to UL 508 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 600 V AC 50/60 Hz conforming to UL 508COMPACT NSX200A3P36KAdownload-catalogue/schneider/distribution/lv431631-compact-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDLV431631.jpgLV431631.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric18943.020011
20C2E48C0-AC9C-4263-BA8A-83F57C0127A07C4D9E7E-E80A-46BB-83DD-92EED2C661BD79F6311B-33D0-4B2B-AD0B-0F94D47627C8circuit breaker ComPact NSX160F, 36 KA at 415 VAC, TMD trip unit 125 A, 3 poles 3dS/LV4306315177114.36Range: ComPact Product name: ComPact NSX Range of product: ComPact NSX100...250 Device short name: NSX160F Product or component type: Circuit breaker Device application: Distribution Number of poles: 3P Protected poles description: 3t [In] rated current: 125 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A [Icu] rated ultimate short-circuit breaking capacity: - 10 kA at 600 V AC 50/60 Hz conforming to UL 508 - 85 kA at 240 V AC 50/60 Hz conforming to UL 508 - 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 - 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 - 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 - 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 - 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 - 35 kA at 480 V AC 50/60 Hz conforming to UL 508 - 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 Performance level: F 36 kA 415 V AC Trip unit name: TM-D Trip unit technology: Thermal-magnetic Trip unit protection functions: LI Control type: Toggle Circuit breaker mounting mode: FixedCOMPACT NSX125A3P36KA download-catalogue/schneider/distribution/lv430631-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDSLV430670.jpgSLV430670.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric16186.40011
211866EBD-9866-4C1F-A1E0-8DFA5094461A7C4D9E7E-E80A-46BB-83DD-92EED2C661BD79F6311B-33D0-4B2B-AD0B-0F94D47627C8circuit breaker ComPact NSX400F, 36 kA at 415 VAC, MicroLogic 2.3 trip unit 400 A, 3 poles 3dS/LV43267652415866.53Range: ComPact Product name: ComPact NSX Range of product: ComPact NSX400...630 Device short name: NSX400F Product or component type: Circuit breaker Device application: Distribution Number of poles: 3P Protected poles description: 3t [In] rated current: 400 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A [Icu] rated ultimate short-circuit breaking capacity: - 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 - 85 kA at 240 V AC 50/60 Hz conforming to UL 508 - 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 - 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 - 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 - 35 kA at 480 V AC 50/60 Hz conforming to UL 508 - 20 kA at 600 V AC 50/60 Hz conforming to UL 508 - 20 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 - 30 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 Performance level: F 36 kA 415 V AC Trip unit name: Micrologic 2.3 Trip unit technology: Electronic Trip unit protection functions: LSoI Control type: Toggle Circuit breaker mounting mode: FixedCOMPACT NSX400A3P36KA download-catalogue/schneider/distribution/lv432676-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDSLV432676-new.jpgSLV432676-new.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric113796.980011
216D9C159-93A9-4C78-8D4E-FD159112FCBA7C4D9E7E-E80A-46BB-83DD-92EED2C661BD79F6311B-33D0-4B2B-AD0B-0F94D47627C8LV429670, Circuit breaker Compact NSX100H, 70 kA at 415 VAC, TMD trip unit 100 A, 3 poles 3dS/LV4296705156747.87Range: ComPact Product name: ComPact NSX Range of product: ComPact NSX100...250 Device short name: NSX100H Product or component type: Circuit breaker Device application: Distribution Number of poles: 3P Protected poles description: 3t [In] rated current: 100 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A [Icu] rated ultimate short-circuit breaking capacity: - 10 kA at 600 V AC 50/60 Hz conforming to UL 508 - 85 kA at 240 V AC 50/60 Hz conforming to UL 508 - 65 kA at 480 V AC 50/60 Hz conforming to UL 508 - 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 - 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 - 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 - 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 - 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 - 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 Performance level: H 70 kA 415 V AC Trip unit name: TM-D Trip unit technology: Thermal-magnetic Trip unit protection functions: LI Control type: Toggle Circuit breaker mounting mode: FixedCOMPACT NSX100A3P70KA download-catalogue/schneider/distribution/lv429670-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/LV429670_360VH_ODA19/20200624T1755/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDSLV429670.jpgSLV429670.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric15867.710011
21DF5D2AC-1EC1-445D-9619-38CF523E59DB7C4D9E7E-E80A-46BB-83DD-92EED2C661BDcircuit breaker ComPact NSX100F, 36 kA at 415 VAC, TMD trip unit 80 A, 3 poles 3dS/LV4296315826016.81Range: Compact Product name: Compact NSX Range of product: NSX100...250 Device short name Compact: NSX100F Product or component type: Circuit breaker Device application: Distribution Poles description: 3P Protected poles description: 3t [In] rated current: 80 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A
[Icu] rated ultimate short-circuit breaking capacity: 10 kA at 600 V AC 50/60 Hz conforming to UL 508 25 kA at 480 V AC 50/60 Hz conforming to UL 508 85 kA at 240 V AC 50/60 Hz conforming to UL 508 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2COMPACT NSX80A3P36KAdownload-catalogue/schneider/distribution/lv429631-compact-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDLV429631.jpgLV429631.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric15232.010011
22DE21798-927A-42B9-9C07-E29CA8DD230F7C4D9E7E-E80A-46BB-83DD-92EED2C661BDswitch disconnector ComPact NSX160 NA, 3 poles, 160 AS/LV4306295824482.9Range: Compact Product name Compact: NSX Product or component type: Switch disconnector Device short name: Compact NSX160NA Poles description: 3P Network type: DC AC
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-3 750 V DC 3 poles in series conforming to IEC 60947-3 500 V DC 2 poles in series conforming to IEC 60947-3 250 V DC 1 pole conforming to IEC 60947-3
[Ie] rated operational current AC-22A: 160 A AC 50/60 Hz 220...690 V AC-23A: 160 A AC 50/60 Hz 220...690 V DC-22A: 160 A DC 250 V 1 pole DC-22A: 160 A DC 500 V 2 poles in series DC-23A: 160 A DC 250 V 1 pole DC-23A: 160 A DC 500 V 2 poles in seriesCOMPACT NSX160A3Pdownload-catalogue/schneider/distribution/lv430629-compact-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/LV430629_360VH_ODA19/20200423T0043/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDLV430629.jpgLV430629.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric13898.170011
2454F1C5B-B674-4F28-8804-1684635064B37C4D9E7E-E80A-46BB-83DD-92EED2C661BDcircuit breaker ComPact NSX250F, 36 kA at 415 VAC, TMD trip unit 250 A, 3 poles 3dS/LV43163058710448.66Range: Compact Product name: Compact NSX Range of product: NSX100...250 Device short name Compact: NSX250F Product or component type: Circuit breaker Device application: Distribution Poles description: 3P Protected poles description: 3t [In] rated current: 250 A at 40 °C [Ue] rated operational: voltage 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA at 240 V AC 50/60 Hz conforming to UL 508 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 480 V AC 50/60 Hz conforming to UL 508 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 600 V AC 50/60 Hz conforming to UL 508COMPACT NSX250A3P36kAdownload-catalogue/schneider/distribution/lv431630-compact-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/LV431630_360VH_ODA19/20200624T0133/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDLV431630.jpgLV431630.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric19085.790011
24DE38494-ECAE-41E0-AB58-6ABEA65BE22A7C4D9E7E-E80A-46BB-83DD-92EED2C661BDcircuit breaker ComPact NSX100F, 36 kA at 415 VAC, TMD trip unit 63 A, 3 poles 3dS/LV4296325825905.25Range: Compact Product name: Compact NSX Range of product: NSX100...250 Device short name Compact: NSX100F Product or component type: Circuit breaker Device application: Distribution Poles description: 3P Protected poles description: 3t [In] rated current: 63 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A
[Icu] rated ultimate short-circuit breaking capacity: 10 kA at 600 V AC 50/60 Hz conforming to UL 508 25 kA at 480 V AC 50/60 Hz conforming to UL 508 85 kA at 240 V AC 50/60 Hz conforming to UL 508 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2COMPACT NSX63A3P36KAdownload-catalogue/schneider/distribution/lv429632-compact-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDLV429632.jpgLV429632.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric151350011
25A4B1D91-0780-476E-9CCF-530953AC17687C4D9E7E-E80A-46BB-83DD-92EED2C661BD79F6311B-33D0-4B2B-AD0B-0F94D47627C8circuit breaker ComPact NSX630H, 70 kA at 415 VAC, MicroLogic 2.3 trip unit 630 A, 3 poles 3dS/LV43289552728176.35Range: ComPact Product name: ComPact NSX Range of product: ComPact NSX400...630 Device short name: NSX630H Product or component type: Circuit breaker Device application: Distribution Number of poles: 3P Protected poles description: 3t [In] rated current: 630 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A [Icu] rated ultimate short-circuit breaking capacity: - 85 kA at 240 V AC 50/60 Hz conforming to UL 508 - 65 kA at 480 V AC 50/60 Hz conforming to UL 508 - 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 - 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 - 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 - 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 - 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 - 20 kA at 600 V AC 50/60 Hz conforming to UL 508 - 20 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 Performance level: H 70 kA 415 V AC Trip unit name: Micrologic 2.3 Trip unit technology: Electronic Trip unit protection functions: LSoI Control type: Toggle Circuit breaker mounting mode: FixedCOMPACT NSX630A3P70KA download-catalogue/schneider/distribution/lv432895-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/NSX630.3P3Tmicro2.3_360V_ODA20/20210130T2154/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDSLV432895.jpgSLV432895.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric124501.170011
25F1594BA-50F3-459A-8116-851FCB57E0727C4D9E7E-E80A-46BB-83DD-92EED2C661BDLV429630, Circuit breaker Compact NSX100F, 36 kA at 415 VAC, TMD trip unit 100 A, 3 poles 3dS/LV4296305826016.81Range: Compact Product name: Compact NSX Range of product: NSX100...250 Device short name Compact: NSX100F Product or component type: Circuit breaker Device application: Distribution Poles description: 3P Protected poles description: 3t [In] rated current: 100 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A
[Icu] rated ultimate short-circuit breaking capacity: 10 kA at 600 V AC 50/60 Hz conforming to UL 508 25 kA at 480 V AC 50/60 Hz conforming to UL 508 85 kA at 240 V AC 50/60 Hz conforming to UL 508 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2COMPACT NSX100A3P36KAdownload-catalogue/schneider/distribution/lv429630-compact-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/LV429630_360VH_ODA19/20200624T1755/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDLV429630.jpgLV429630.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric15232.010011
2687FCF77-08EA-4155-A1CB-FF74CFFAC3857C4D9E7E-E80A-46BB-83DD-92EED2C661BD79F6311B-33D0-4B2B-AD0B-0F94D47627C8LV430310, Circuit breaker Compact NSX160B, 25 kA at 415 VAC, TMD trip unit 160 A, 3 poles 3dS/LV4303105166896.76Range: ComPact Product name: ComPact NSX Range of product: ComPact NSX100...250 Device short name: NSX160B Product or component type: Circuit breaker Device application: Distribution Number of poles: 3P Protected poles description: 3t [In] rated current: 160 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A [Icu] rated ultimate short-circuit breaking capacity: - 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 - 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 - 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 - 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 Performance level: B 25 kA 415 V AC Trip unit name: TM-D Trip unit technology: Thermal-magnetic Trip unit protection functions: LI Control type: Toggle Circuit breaker mounting mode: FixedCOMPACT NSX160A3P25kA download-catalogue/schneider/distribution/lv430310-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/LV430310_360VH_ODA19/20200716T2200/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDSLV430310.jpgSLV430310.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric15997.180011
271B03024-5EFB-43C3-8A74-11AD6220E4317C4D9E7E-E80A-46BB-83DD-92EED2C661BD79F6311B-33D0-4B2B-AD0B-0F94D47627C8circuit breaker basic frame, ComPact NSX100H, 70 kA at 415 VAC 50/60 Hz, 100 A, without trip unit, 3 polesS/LV4290045144212.3Range: ComPact Range of product: ComPact NSX100...250 Device short name: NSX100H Product or component type: Basic frame Device application: Distribution Circuit breaker name: Compact NSX100H Number of poles: 3P [In] rated current: 100 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A [Icu] rated ultimate short-circuit breaking capacity" - 10 kA at 600 V AC 50/60 Hz conforming to UL 508 - 85 kA at 240 V AC 50/60 Hz conforming to UL 508 - 65 kA at 480 V AC 50/60 Hz conforming to UL 508 - 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 - 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 - 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 - 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 - 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 - 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 Performance level: H 70 kA 415 V AC Control type: Toggle Mounting mode: FixedCOMPACT NSX100A3P70KA download-catalogue/schneider/distribution/lv429004-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDSLV429004.jpgSLV429004.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric13662.870011
274A612FE-128E-4083-9BF8-B24E9D21376C7C4D9E7E-E80A-46BB-83DD-92EED2C661BD79F6311B-33D0-4B2B-AD0B-0F94D47627C8circuit breaker ComPact NSX400H, 70 kA at 415 VAC, MicroLogic 2.3 trip unit 400 A, 3 poles 3dS/LV43269552517828.36Range: ComPact Product name: ComPact NSX Range of product: ComPact NSX400...630 Device short name: NSX400H Product or component type: Circuit breaker Device application: Distribution Number of poles: 3P Protected poles description: 3t [In] rated current: 400 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A [Icu] rated ultimate short-circuit breaking capacity: - 85 kA at 240 V AC 50/60 Hz conforming to UL 508 - 65 kA at 480 V AC 50/60 Hz conforming to UL 508 - 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 - 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 - 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 - 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 - 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 - 20 kA at 600 V AC 50/60 Hz conforming to UL 508 - 20 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 Performance level: H 70 kA 415 V AC Trip unit name: Micrologic 2.3 Trip unit technology: Electronic Trip unit protection functions: LSoI Control type: Toggle Circuit breaker mounting mode: FixedCOMPACT NSX400A3P70KA download-catalogue/schneider/distribution/lv432695-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDSLV432695.jpgSLV432695.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric115502.920011
27AD35E20-6C47-4219-847D-61B22C989CCF7C4D9E7E-E80A-46BB-83DD-92EED2C661BDswitch disconnector ComPact NSX250 NA, 3 poles, 250 AS/LV4316295876585.081.0000Range: Compact Product name Compact: NSX Product or component type: Switch disconnector Device short name: Compact NSX250NA Poles description: 3P Network type: DC AC
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-3 750 V DC 3 poles in series conforming to IEC 60947-3 500 V DC 2 poles in series conforming to IEC 60947-3 250 V DC 1 pole conforming to IEC 60947-3
[Ie] rated operational current AC-22A: 160 A AC 50/60 Hz 220...690 V AC-23A: 160 A AC 50/60 Hz 220...690 V DC-22A: 160 A DC 250 V 1 pole DC-22A: 160 A DC 500 V 2 poles in series DC-23A: 160 A DC 250 V 1 pole DC-23A: 160 A DC 500 V 2 poles in seriesCOMPACT NSX250A3Pdownload-catalogue/schneider/distribution/lv431629-compact-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/LV431629_360VH_ODA19/20200423T0043/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDLV431629.jpgLV431629.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric15726.160011
2812CA550-4BC8-416A-B8DB-E51C47535B997C4D9E7E-E80A-46BB-83DD-92EED2C661BD79F6311B-33D0-4B2B-AD0B-0F94D47627C8circuit breaker basic frame, ComPact NSX100F, 36 kA at 415 VAC 50/60 Hz, 100 A, without trip unit, 3 polesS/LV4290035133481.251.0000Range: ComPact Range of product: ComPact NSX100...250 Device short name: NSX100F Product or component type: Basic frame Device application: Distribution Circuit breaker name: Compact NSX100F Number of poles: 3P [In] rated current: 100 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A [Icu] rated ultimate short-circuit breaking capacity: - 10 kA at 600 V AC 50/60 Hz conforming to UL 508 - 25 kA at 480 V AC 50/60 Hz conforming to UL 508 - 85 kA at 240 V AC 50/60 Hz conforming to UL 508 - 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 - 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 - 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 - 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 - 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 - 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 Performance level: F 36 kA 415 V AC Control type: Toggle Mounting mode: FixedCOMPACT NSX100A3P36KA download-catalogue/schneider/distribution/lv429003-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDSLV429003.jpgSLV429003.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric13027.170011
28A34F93C-7C78-4A8D-A9EA-02D5183AAC587C4D9E7E-E80A-46BB-83DD-92EED2C661BD79F6311B-33D0-4B2B-AD0B-0F94D47627C8LV430840, Circuit breaker Compact NSX160N, 50 kA at 415 VAC, TMD trip unit 160 A, 3 poles 3dS/LV4308405227571.38Range: ComPact Product name: ComPact NSX Range of product: ComPact NSX100...250 Device short name: NSX160N Product or component type: Circuit breaker Device application: Distribution Number of poles: 3P Protected poles description: 3t [In] rated current: 160 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category ACOMPACT NSX160A3P50KAdownload-catalogue/schneider/distribution/lv430840-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/LV430840_360VH_ODA19/20200624T0133/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDSLV430840.jpgSLV430840.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric16583.810011
28DFF3C9B-3156-428D-818B-1D1FD724440A7C4D9E7E-E80A-46BB-83DD-92EED2C661BD79F6311B-33D0-4B2B-AD0B-0F94D47627C8circuit breaker ComPact NSX160H, 70 kA at 415 VAC, TMD trip unit 160 A, 3 poles 3dS/LV4306705198074.05Range: ComPact Product name: ComPact NSX Range of product: ComPact NSX100...250 Device short name: NSXm 160H Product or component type: Circuit breaker Device application: Distribution Number of poles: 3P Protected poles description: 3t [In] rated current: 160 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A [Icu] rated ultimate short-circuit breaking capacity: - 10 kA at 600 V AC 50/60 Hz conforming to UL 508 - 85 kA at 240 V AC 50/60 Hz conforming to UL 508 - 65 kA at 480 V AC 50/60 Hz conforming to UL 508 - 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 - 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 - 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 - 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 - 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 - 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 Performance level: H 70 kA 415 V AC Trip unit name: TM-D Trip unit technology: Thermal-magnetic Trip unit protection functions: LI Control type: Toggle Circuit breaker mounting mode: FixedCOMPACT NSX160A3P70KA download-catalogue/schneider/distribution/lv430670-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/LV430670_360VH_ODA19/20200624T0133/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDSLV430670.jpgSLV430670.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric17020.910011
296FB4FB2-8C6D-4321-9367-0F11F96205077C4D9E7E-E80A-46BB-83DD-92EED2C661BD79F6311B-33D0-4B2B-AD0B-0F94D47627C8LV430632 - Circuit breaker Compact NSX160F, 36 KA at 415 VAC, TMD trip unit 100 A, 3 poles 3d.S/LV4306325187105.442.0000Range: ComPact Product name: ComPact NSX Range of product: ComPact NSX100...250 Device short name: NSX160F Product or component type: Circuit breaker Device application: Distribution Number of poles: 3P Protected poles description: 3t [In] rated current: 100 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A [Icu] rated ultimate short-circuit breaking capacity: - 10 kA at 600 V AC 50/60 Hz conforming to UL 508 - 85 kA at 240 V AC 50/60 Hz conforming to UL 508 - 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 - 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 - 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 - 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 - 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 - 35 kA at 480 V AC 50/60 Hz conforming to UL 508 - 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 Performance level: F 36 kA 415 V AC Trip unit name: TM-D Trip unit technology: Thermal-magnetic Trip unit protection functions: LI Control type: Toggle Circuit breaker mounting mode: FixedCOMPACT NSX100A3P36KA download-catalogue/schneider/distribution/lv430632-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDSLV430632.jpgSLV430632.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric16178.640011
2AEAF125D-F102-4DE4-8DD3-44DBE26719E67C4D9E7E-E80A-46BB-83DD-92EED2C661BD79F6311B-33D0-4B2B-AD0B-0F94D47627C8circuit breaker ComPact NS800N, 50 kA at 415 VAC, Micrologic 2.0 trip unit, 800 A, fixed, 3 poles 3dS/3346651339996.85Range: ComPact Product name: ComPact NS Range of product: ComPact NS630b...1600 Device short name: Compact NS800N Product or component type: Circuit breaker Device application: Distribution Number of poles: 3P Protected poles description: 3d (In) rated current up to 65 °C: 800 A at 50 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category B [Icu] rated ultimate short-circuit breaking capacity: - 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 - 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 - 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 - 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 - 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 Performance level: N 50 kA 415 V AC Trip unit name: Micrologic 2.0 Trip unit technology: Electronic Trip unit protection functions: LI Control type: Rotary handle Toggle Circuit breaker mounting mode: FixedCOMPACT NS800A3P50KA download-catalogue/schneider/distribution/33466-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDS33466.jpgS33466.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric134779.870011
2B6570AA5-8872-4101-B6F1-A73174606CCE7C4D9E7E-E80A-46BB-83DD-92EED2C661BDcircuit breaker ComPact NSX160F, 36 KA at 415 VAC, TMD trip unit 160 A, 3 poles 3dS/LV4306305877114.36Range: Compact Product name Compact: NSX Product or component type: Switch disconnector Device short name: Compact NSX160NA Poles description: 3P Network type: DC AC
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-3 750 V DC 3 poles in series conforming to IEC 60947-3 500 V DC 2 poles in series conforming to IEC 60947-3 250 V DC 1 pole conforming to IEC 60947-3
[Ie] rated operational current AC-22A: 160 A AC 50/60 Hz 220...690 V AC-23A: 160 A AC 50/60 Hz 220...690 V DC-22A: 160 A DC 250 V 1 pole DC-22A: 160 A DC 500 V 2 poles in series DC-23A: 160 A DC 250 V 1 pole DC-23A: 160 A DC 500 V 2 poles in seriesCOMPACT NSX160A3P36KAdownload-catalogue/schneider/distribution/lv430630-compact-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/LV430630_360VH_ODA19/20200624T0133/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDLV430630.jpgLV430630.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric16186.40011
2C027DB3E-B436-460C-924C-AF8F01297BB67C4D9E7E-E80A-46BB-83DD-92EED2C661BDcircuit breaker ComPact NSX630N, 50 kA at 415 VAC, MicroLogic 2.3 trip unit 630 A, 3 poles 3dS/LV43289359226326.63Range: Compact Product name: Compact NSX Range of product: NSX400...630 Device short name: Compact NSX630N Product or component type: Circuit breaker Device application: Distribution Poles description: 3P Protected poles description: 3t [In] rated current: 630 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA at 240 V AC 50/60 Hz conforming to UL 508 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 480 V AC 50/60 Hz conforming to UL 508 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 600 V AC 50/60 Hz conforming to UL 508COMPACT NSX630A3P50KAdownload-catalogue/schneider/distribution/lv432893-compact-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDLV432893.jpgLV432893.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric122892.720011
2E8E09E9F-E399-4456-AB7C-9D235F0A5F207C4D9E7E-E80A-46BB-83DD-92EED2C661BD79F6311B-33D0-4B2B-AD0B-0F94D47627C8iCT 25A 2NO 230...240V 50Hz contactorS/3347251441789.92Range: ComPact Product name: ComPact NS Range of product: ComPact NS630b...1600 Device short name: Compact NS1000N Product or component type: Circuit breaker Device application: Distribution Number of poles: 3P Protected poles description: 3d (In) rated current up to 65 °C: 1000 A at 50 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category B [Icu] rated ultimate short-circuit breaking capacity - 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 - 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 - 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 - 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 - 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 Performance level: N 50 kA 415 V AC Trip unit name: Micrologic 2.0 Trip unit technology: Electronic Trip unit protection functions: LI Control type: Rotary handle Toggle Circuit breaker mounting mode: FixedCOMPACT NS1000A3P50KA download-catalogue/schneider/distribution/33472-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDS33472.jpgS33472.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric136339.060011
2EABA8332-9DC8-4213-884F-D8263E3D84EB7C4D9E7E-E80A-46BB-83DD-92EED2C661BD79F6311B-33D0-4B2B-AD0B-0F94D47627C8circuit breaker ComPact NSX630F, 36 kA at 415 VAC, MicroLogic 2.3 trip unit 630 A, 3 poles 3dS/LV43287652624645.05Range: ComPact Product name: ComPact NSX Range of product: ComPact NSX400...630 Device short name: NSX630F Product or component type: Circuit breaker Device application: Distribution Number of poles: 3P Protected poles description: 3t [In] rated current: 630 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A [Icu] rated ultimate short-circuit breaking capacity: - 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 - 85 kA at 240 V AC 50/60 Hz conforming to UL 508 - 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 - 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 - 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 - 35 kA at 480 V AC 50/60 Hz conforming to UL 508 - 20 kA at 600 V AC 50/60 Hz conforming to UL 508 - 20 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 - 30 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 Performance level: F 36 kA 415 V AC Trip unit name: Micrologic 2.3 Trip unit technology: Electronic Trip unit protection functions: LSoI Control type: Toggle Circuit breaker mounting mode: FixedCOMPACT NSX630A3P36KA download-catalogue/schneider/distribution/lv432876-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/LV432876_360V_ODA20/20200916T2234/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDSLV432876.jpgSLV432876.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric121430.480011
2EAEF480A-1C87-42FC-B7E6-E9F1C9081F5E7C4D9E7E-E80A-46BB-83DD-92EED2C661BD79F6311B-33D0-4B2B-AD0B-0F94D47627C8LV432956, Switch disconnector Compact NSX630NA, 3 poles, 630 A, AC22A, AC23AS/LV43295652816019.29Range: ComPact Product name: ComPact NSX Product or component type: Switch disconnector Device short name: Compact NSX630NA Poles description: 3P Network type: AC [Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-3 [Ie] rated operational current: - AC-22A: 630 A AC 50/60 Hz 220...690 V - AC-23A: 630 A AC 50/60 Hz 220...690 V [Ui] rated insulation voltage: 800 V AC 50/60 Hz conforming to IEC 60947-3 [Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947-3 [Ith] conventional free air thermal current: 630 A at 60 °C [Icm] rated short-circuit making capacity: - 330 kA with upstream protection circuit breaker - 8.5 kA switch-disconnector alone Breaking capacity code: NA Suitability for isolation: - Yes conforming to EN 60947-3 - Yes conforming to IEC 60947-3 Contact position indicator: Yes Visible break: No Pollution degree: 3 conforming to IEC 60664-1COMPACT NSX630A3P download-catalogue/schneider/distribution/lv432956-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/LV432956_360V_ODA20/20200916T2234/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDSLV432956.jpgSLV432956.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric113929.820011
2F0F8324B-EA9E-4774-A9DC-077B72767C177C4D9E7E-E80A-46BB-83DD-92EED2C661BDcircuit breaker ComPact NSX400N, 50 kA at 415 VAC, MicroLogic 2.3 trip unit 400 A, 3 poles 3dS/LV43269359216800.73Range: Compact Product name: Compact NSX Range of product: NSX400...630 Device short name: Compact NSX400N Product or component type: Circuit breaker Device application: Distribution Poles description: 3P Protected poles description: 3t [In] rated current: 400 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA at 240 V AC 50/60 Hz conforming to UL 508 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 600 V AC 50/60 Hz conforming to UL 508 50 kA at 480 V AC 50/60 Hz conforming to UL 508 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2COMPACT NSX400A3P50KAdownload-catalogue/schneider/distribution/lv432693-compact-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDLV432693.jpgLV432693.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric114609.330011
2FFC9CA0B-F7B6-411F-9CBC-92CF3E0038127C4D9E7E-E80A-46BB-83DD-92EED2C661BD79F6311B-33D0-4B2B-AD0B-0F94D47627C8circuit breaker ComPact NSX250H, 70 kA at 415 VAC, TMD trip unit 250 A, 3 poles 3dS/LV43167052311849.95Range: ComPact Product name: ComPact NSX Range of product: ComPact NSX100...250 Device short name: NSX250H Product or component type: Circuit breaker Device application: Distribution Number of poles: 3P Protected poles description: 3t [In] rated current: 2500 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz Network type: AC Network frequency: 50/60 Hz Suitability for isolation: Yes conforming to EN/IEC 60947-2 Utilisation category: Category ACOMPACT NSX250A3P70KAdownload-catalogue/schneider/distribution/lv431670-document.pdf1|2024-09-19:04:00<3dobject>https://visuals.se.com/LV431670_360VH_ODA19/20200624T0133/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker7C4D9E7E-E80A-46BB-83DD-92EED2C661BDSLV431670.jpgSLV431670.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric110304.30011
2347079E5-81BD-4A58-8415-8B3C81FFAE0ECDF8A3B8-737A-4449-B6CA-07C15CEE6FB279F6311B-33D0-4B2B-AD0B-0F94D47627C8LV429515 - Short terminal shield, Compact NSX, EasyPact CVS, 3 poles, pitch 35 mm. Compact NSX the safest and most reliable protection.S/LV429515532383.768.0000Product or component type: Short terminal shield Range compatibility: - ComPact NSX100 - ComPact NSX160 - ComPact NSX250 - Compact NSX100 DC - Compact NSX160 DC - Compact NSX250 DC - EasyPact CVS100 - EasyPact CVS160 - EasyPact CVS250 Accessory / separate part type: Insulation accessories Poles description: 3P Quantity per set: 1COMPACT NSX3P https://eref.se.com/ww/en/scope/product-pdf/LV4295151|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker Accessories2B876BF7-BF26-4B13-877D-39BCAC1BA6BASLV429515.jpgSLV429515.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric1333.70011
24A28DA8E-2168-4203-B728-8DBD685F670ACDF8A3B8-737A-4449-B6CA-07C15CEE6FB279F6311B-33D0-4B2B-AD0B-0F94D47627C8trip unit TM50D for ComPact NSX 100/160 circuit breakers, thermal magnetic, rating 50 A, 3 poles 3dS/LV4290335282424.041.0000Range: ComPact Range of product: ComPact NSX100...250 DC ComPact NSX100...250 Product or component type: Trip unit Trip unit name: TM-D Trip unit technology: Thermal-magnetic Range compatibility: - ComPact NSX100 - ComPact NSX160 - ComPact NSX100 DC Device application: Distribution Number of poles: 3P Protected poles description: 3t Trip unit protection functions: LI Protection type: - L : for overload protection (thermal) - I : for short-circuit protection (magnetic) Trip unit rated current: 50 A at 40 °C [Ue] rated operational voltage: 690 V AC 50/60 Hz 750 V DC Network type: AC/DC Network frequency: 50/60 HzCOMPACT NSX50A3P download-catalogue/schneider/distribution/lv429033-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker Accessories2B876BF7-BF26-4B13-877D-39BCAC1BA6BASLV429033.jpgSLV429033.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric12107.860011
250448FC6-DFD5-4EE4-BBBC-1AE41F04E744CDF8A3B8-737A-4449-B6CA-07C15CEE6FB279F6311B-33D0-4B2B-AD0B-0F94D47627C8MX shunt release, ComPacT NSX, rated voltage 110/130 VAC 50/60 Hz, screwless spring terminal connectionsS/LV4293865302380.041.0000Device short name: MX Product or component type: Voltage release Device application: Control Range compatibility: - ComPact NSX - EasyPact CVS - PowerPact Multistandard - ComPact NSX DC Voltage release type: Shunt trip release [Uc] control circuit voltage: 110...130 V AC 50/60 HzCOMPACT NSX https://eref.se.com/ww/en/scope/product-pdf/LV4293861|2024-09-19:04:00<3dobject>https://visuals.se.com/LV429386_360VH_ODA19/20200327T0924/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker Accessories2B876BF7-BF26-4B13-877D-39BCAC1BA6BASLV429386.jpgSLV429386.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric12069.60011
2B9CCF428-5C99-4E73-9D2E-9B4177CF826ECDF8A3B8-737A-4449-B6CA-07C15CEE6FB2extended rotary handle, ComPact NSX 100/160/250, black handle, shaft length 185 to 600 mm, IP55S/LV4293385822918.17Range of product: NSX100...250 Easypact CVS100...250 Product or component type: Rotary handle Accessory / separate part type: Control accessories Handle front plate colour: Black Rotary handle padlocking: Padlock in OFF position 1 to 3 padlocks Rotary handle mounting location: Front Handle colour: Black Rotary handle mounting style: ExtendedCOMPACT NSXhttps://eref.se.com/ww/en/scope/product-pdf/LV4293381|2024-09-19:04:00<3dobject>https://visuals.se.com/LV429338_360V_ODA19/20200922T0048/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker Accessories7C4D9E7E-E80A-46BB-83DD-92EED2C661BDLV429338.jpgLV429338.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric12537.540011
2D2057D12-F827-4162-8C25-B9A5068F27EFCDF8A3B8-737A-4449-B6CA-07C15CEE6FB279F6311B-33D0-4B2B-AD0B-0F94D47627C8MN undervoltage release, ComPacT NSX, rated voltage 220/240 VAC 50/60 Hz, 208/277 VAC 60 Hz, screwless spring terminal connectionsS/LV4294075313433.87Device short name: MX Product or component type: Voltage release Device application: Control Range compatibility: - ComPact NSX - EasyPact CVS - PowerPact Multistandard - ComPact NSX DC Voltage release type: Undervoltage release [Uc] control circuit voltage: - 208...277 V AC 60 Hz - 220...240 V AC 50/60 HzCOMPACT NSXhttps://eref.se.com/ww/en/scope/product-pdf/LV4294071|2024-09-19:04:00<3dobject>https://visuals.se.com/LV429407_360VH_ODA19/20200327T0924/3603dobject>1:2023-05-10_16-41-39Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker Accessories2B876BF7-BF26-4B13-877D-39BCAC1BA6BASLV429407.jpgSLV429407.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric12985.970011
2DBC3F5AB-C7CA-4E66-BDA9-01DE188CAD9ECDF8A3B8-737A-4449-B6CA-07C15CEE6FB2LV432598 - Extended rotary handle, Compact NSX 400/630, PowerPact Multistandard L, EasyPact CVS 400/630, black standard handle, IP55S/LV4325985873236.342.0000Range of product: Easypact CVS400...630 NSX400...630 PowerPact multistandard TeSys GV6 Product or component type: Rotary handle Accessory / separate part type: Control accessories Handle front plate colour: Black Rotary handle padlocking: 1 to 3 padlocks Padlock in OFF position Rotary handle mounting location: FrontCOMPACT NSXhttps://eref.se.com/ww/en/scope/product-pdf/LV4325981|2024-09-19:04:00<3dobject>https://visuals.se.com/EXT-STD-ROT-HANDLE_NSX_360V/20201005T2230/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker Accessories7C4D9E7E-E80A-46BB-83DD-92EED2C661BDLV432598.jpgLV432598.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric12814.210011
2EDE86964-785A-4DEA-A7DF-16E9109C644ACDF8A3B8-737A-4449-B6CA-07C15CEE6FB279F6311B-33D0-4B2B-AD0B-0F94D47627C8direct rotary handle, ComPact NSX 100/160/250, black handle, IP40S/LV4293375292641.313.0000Range of product: ComPact NSX100...250 Product or component type: Rotary handle Accessory / separate part type: Control accessories Handle front plate colour: Black Rotary handle padlocking: - Padlock in OFF position - 1 to 3 padlocks Rotary handle mounting location: FrontCOMPACT NSX https://eref.se.com/ww/en/scope/product-pdf/LV4293371|2024-09-19:04:00<3dobject>https://visuals.se.com/LV429337_360V_ODA19/20200924T0105/3603dobject>Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker Accessories2B876BF7-BF26-4B13-877D-39BCAC1BA6BASLV429337.jpgSLV429337.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric12296.790011
2F3A2A019-B95C-48B0-A912-87FCA26A67DBCDF8A3B8-737A-4449-B6CA-07C15CEE6FB279F6311B-33D0-4B2B-AD0B-0F94D47627C8extended rotary handle, ComPact NS630b to NS1600 fixed, black handle, shaft length 218 to 605 mm, IP55S/33878516044.933.0000Range of product: ComPact NS630b...1600 Product or component type: Rotary handle Accessory / separate part type: Control accessories Handle front plate colour: Black Rotary handle padlocking: Padlock in OFF position Rotary handle mounting location: FrontCOMPACT NS download-catalogue/schneider/distribution/33878-document.pdf1|2024-09-19:04:00Schneider Electric\Distribution\Circuit Breaker and Accessories\Moulded Case Circuit Breaker AccessoriesCDF8A3B8-737A-4449-B6CA-07C15CEE6FB2S33878.jpgS33878.jpg(PATHUPLOAD)\__upload\MagnetStore\Catalogue\imagesSchneider Electric15256.460011